APC INROW SC SYSTEM 1

Forsiden / APC INROW SC SYSTEM 1

APC INROW SC SYSTEM 1
INROW SC 50HZ 1PH 1 NETSHELTER SX RACK 600MM PTO

Varenr.: RACSC112E
  • Kapasitet 0VA
  • Produkt Tilbehør
170 261,-
136 208,80 ekskl. mva
I butikk Ikke på lager Hovedlager Ikke på lager På fjernlager Forventet leveringsdato 03.10.2017
Antall:
FIRMALEIE (inkl. mva)
36-mnd 
5 736,-/mnd
Ved FIRMALEIE gjelder: Etableringsgebyr 1 238,-, faktureringsgebyr 119,-/mnd, minimumsordre 10 000,-. Frakt og mva. kommer i tillegg. Forutsetter kredittgodkjenning. Firmaleie kan velges som en betalingsmåte når du går til kassen.
Beskrivelse

InRow Direct Expansion


InRow SC System 1 InRow SC 50Hz 1PH, 1 NetShelter SX Rack 600mm, with Front and Rear Containment

Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

Technical Specifications

General

Compressor Type: Rotary
Air Discharge Patterns: Horizontal
Intake Air: Rear Return
Refrigerant Charge: 1.36 KG
Air Flow: 566.34 lps
Amp Draw In-Rush: 65A
Condensate Pump Capacity: 0.002 lps

Input

Number of Power Cords: 1
Nominal Input Voltage: 200,208,220,230
Input Power: 2390 Watts
Input Frequency: 50 Hz
Rack Height: 42U
Input Connections
IEC 309 16A 2P+E

Communications & Management

Control panel: Multi-function LCD status and control console

Physical

Maximum Height: 1991.00 mm
Maximum Width: 900.00 mm
Maximum Depth: 1477.00 mm
Net Weight: 374.23 KG
Color: Black

Environmental

Audible noise at 1 meter from surface of unit: 70.00 dBA

Conformance

Standard Warranty:1 year (parts only)

Features

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Reduces the risk of hot spots at the rack level

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Variable speed fans reduce energy consumption during off-peak cooling periods.

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.

Modular design provides scalable solutions to add cooling as demand increases.

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-time display of current and available cooling.

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.