APC SERVICE BYPASS PANEL 230V

Forsiden / APC SERVICE BYPASS PANEL 230V

APC SERVICE BYPASS PANEL 230V
16A BBM HARDWIRE SVCS

Varenr.: SBP3000RMHW
EAN: 731304283225
  • Type PDU
4 009,-
3 207,20 ekskl. mva
I butikk Ikke på lager Hovedlager Ikke på lager På fjernlager Forventet leveringsdato 09.10.2017
Antall:

Privat finansiering

Fra 201,-/mnd (33 mnd)
Utsett betalingen i 4-6 mnd
Velg finansiering i kassen
Les mer
FIRMALEIE (inkl. mva)
36-mnd 
136,-/mnd
Ved FIRMALEIE gjelder: Etableringsgebyr 1 238,-, faktureringsgebyr 119,-/mnd, minimumsordre 10 000,-. Frakt og mva. kommer i tillegg. Forutsetter kredittgodkjenning. Firmaleie kan velges som en betalingsmåte når du går til kassen.
Beskrivelse

APC SERVICE BYPASS PDU, 230V 16AMP Hardwire


APC Maintenance Bypass Panels , Input: 230V , Output: 230V , Output Connections: Hard Wire 3-wire (H N + G),IEC Jumpers

Output

Nominal Output Voltage: 230V
Maximum Total Current Draw per Phase: 16A
Output Connections: (1) Hard Wire 3-wire (H N + G) (1) IEC Jumpers
Overload Protection: Yes
Cord Length: 1 meters

Input

Nominal Input Voltage: 230V
Input Frequency: 50/60 Hz
Acceptable Input Voltage: 220-240 VAC
Maximum Line Current per phase: 16A
Maximum Input Current per phase: 16A
Load Capacity :3000 VA
Load Power Factor Range: 0 to 1

Physical

Net Weight: 2.27 KG
Maximum Height: 89.00 mm
Maximum Width: 432.00 mm
Maximum Depth: 76.00 mm
Shipping Weight: 3.45 KG
Shipping Height: 151.00 mm
Shipping Width: 463.00 mm
Shipping Depth: 295.00 mm
Color: Black
Units per Pallet: 56.00

Environmental

Operating Environment: 0 - 40 °C
Operating Relative Humidity: 0 - 95%
Operating Elevation: 0-4500 meters
Storage Temperature: -15 - 45 °C
Storage Relative Humidity: 0 - 95%
Storage Elevation: 0-15000 meters

Conformance

Regulatory Approvals: VDE
Standard Warranty: 2 years repair or replace
Environmental Compliance: RoHS,REACH: Contains No SVHCs

Features

Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.

(3) Breaker maintenance bypass panel to isolate the UPS from the critical load

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.