APC SMART-UPS RT 1500VA 120V SURTA1500XL APC Smart-UPS RT, 1500VA/1050W, Input 120V/Output 120V, Interface Port DB-9 RS-232, Smart-Slot, USB, Extended runtime model, Rack Height 2 U Includes: CD with software, Documentation CD, Installation Guide, Smart UPS signalling RS-232 cable, USB cable, User Manual Features Availability Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Manageability Network manageable Monitor and control the UPS and access environmental information remotely via included PowerChute software or APC's Network Management Card with temperature monitoring (included in all models above 3kVA). InfraStruXure Manager compatible Enables centralized management via APC's InfraStruXure Manager. SmartSlot Customize UPS capabilities with management cards. LED status indicators Enables quick understanding and response to visual indicators showing UPS status. Serial Connectivity Provides management of the UPS via a serial port. Adaptability Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Flash-upgradeable firmware Easy implementation of new firmware upgrades. Serviceability User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Disconnected battery notification Warns when a battery is not available to provide backup power. Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. Protection Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage Cold-start capable Provides temporary battery power when the utility power is out. Resettable circuit breakers Enables quick recovery from UPS overload events. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Output Output Power Capacity 1050 Watts / 1500 VA Max Configurable Power 1050 Watts / 1500 VA Nominal Output Voltage 120V Efficiency at Full Load 90% Output Voltage Distortion Less than 3% Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Crest Factor 3 : 1 Waveform Type Sine wave Output Connections (6) NEMA 5-15R Input Bypass Built-in Bypass Nominal Input Voltage 120V Input Frequency 50/60 Hz +/- 5 Hz (auto sensing) Input Connections NEMA 5-15P Cord Length 6 feet ( 1.83 meters) Input voltage range for main operations 90 - 150V Batteries & Runtime Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Included Battery Modules 1 Typical recharge time 3 hour(s) Replacement battery cartridge RBC57, SURTA48XLBP, SURTA48RMXLBP RBC™ Quantity 1 Typical Backup Timeat Half Load 22.2 minutes (525 Watts) Typical Backup Timeat Full Load 8.6 minutes (1050 Watts) Runtime Chart Smart-UPS RT Extended Run Options APC SMART-UPS RT 1500VA 120V Communications & Management Interface Port(s) DB-9 RS-232,Smart-Slot,USB Available SmartSlot™ Interface Quantity 1 Control panel LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 540 Joules Physical Maximum Height 17.00 inches (432 mm) Maximum Width 3.35 inches ( 85 mm) Maximum depth 22.00 inches (559 mm) Rack Height 2U Net Weight 60.50 lbs. ( 27.50 kg) Shipping Weight 69.00 lbs. ( 31.36 kg) Shipping Height 10.25 inches (260 mm) Shipping Width 24.00 inches (610 mm) Shipping Depth 29.00 inches (737 mm) Color Black Units per Pallet 8.00 Environmental Operating Environment 32 - 104 °F (0 - 40 °C) Operating Relative Humidity 0 - 95% Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature -4 - 122 °F (-20 - 50 °C) Storage Relative Humidity 0 - 95% Storage Elevation 0-50000 feet (0-15000 meters) Audible noise at 1 meter from surface of unit 45 dBA Online Thermal Dissipation 393 BTU/hr Conformance Regulatory Approvals BSMI,CSA,FCC Part 15 Class B,UL 1778 Standard Warranty 2 years repair or replace