Vennligst vent...
Produktet ble lagt i handlekurven. Se handlekurven her
Tom handlekurv

APC SYMMETRA PX 125KW SCALABLE TO 250KW WITHOUT BYPASS DISTRIBUTIO ACCS

Forsiden APC SYMMETRA PX 125KW SCALABLE TO 250KW WITHOUT BYPASS DISTRIBUTIO ACCS
APC SYMMETRA PX 125KW SCALABLE TO 250KW WITHOUT BYPASS DISTRIBUTIO ACCS (SY125K250D-NB)

APC SYMMETRA PX 125KW SCALABLE TO 250KW WITHOUT BYPASS DISTRIBUTIO ACCS

Varenr.:
SY125K250D-NB
  • Kapasitet 500kVA
  • Produkt Ekstern UPS
1 199 805,-
959 844,- ekskl. mva
Hovedlager Bestillingsvare Butikk Sarpsborg Bestillingsvare Butikk Sørlandssenteret Bestillingsvare Butikk Kristiansand Bestillingsvare Leverandør Bestillingsvare
Beskrivelse

APC Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable


A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments. Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection.

General

  • Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%

Output

  • Output Power Capacity 125 kW / 125 kVA
  • Max Configurable Power 500 kW / 500 kVA
  • Nominal Output Voltage 400V 3PH,480V 3PH
  • Efficiency at Full Load 96%
  • Output Voltage Distortion Less than 5% at full load
  • Output Frequency (sync to mains) 50 Hz,60 Hz
  • Crest Factor Unlimited
  • Waveform Type Sine wave
  • Output Connections (1) Hard Wire 4-wire (3PH + G)
  • (1) Hard Wire 5-wire (3PH + N + G)
  • Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
  • Output Voltage THD < 2% for 0 to 100% linear load and < 6% for full n
  • Overload Operation 10 minutes @ 125% and 30 seconds @ 150%
  • Efficiency at Half Load 96%
  • Bypass Built-in Maintenance Bypass,Built-in Static Bypass

Input

  • Nominal Input Voltage 400V 3PH,480V 3PH
  • Input Frequency 40 - 70 Hz (auto sensing)
  • Input Connections Hard Wire 4-wire (3PH + G)
  • Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations 408 - 552 (480)V
  • Other Input Voltages 415
  • Input Total Harmonic Distortion Less than 5% for full load
  • Type of Input Protection Required 3-pole breaker

Batteries & Runtime

  • Battery Type No internal battery - uses external battery system
  • Efficiency in Battery Operation 96%

Communications & Management

  • Interface Port(s) SYPX250-500_Parallel
  • Available SmartSlot™ Interface Quantity 3
  • Control panel Touch Screen LCD User Interface
  • Emergency Power Off (EPO) Optional

Physical

  • Maximum Height 1991.00 mm
  • Maximum Width 1600.00 mm
  • Maximum Depth 1070.00 mm
  • Net Weight 1233.18 KG
  • Shipping Weight 1380.45 KG
  • Shipping Height 2150.00 mm
  • Shipping Width 1870.00 mm
  • Shipping Depth 1270.00 mm
  • Color Black

Environmental

  • Operating Environment 0 - 40 °C
  • Operating Relative Humidity 0 - 95%
  • Operating Elevation 0-999.9 meters
  • Storage Temperature -30 - 70 °C
  • Storage Relative Humidity 0 - 95%
  • Storage Elevation 0-15000 meters
  • Audible noise at 1 meter from surface of unit 54.00 dBA
  • Online Thermal Dissipation 15473.00 BTU/hr
  • Protection Class NEMA 1,IP 20

Conformance

  • Regulatory Approvals cUL Listed,CE,EN/IEC 62040-2,EN/IEC 62040-3,EN/IEC 62040-1-1,UL 1778,UL 60950-1,UL Listed
  • Standard Warranty 1 year on-site repair or replace with factory authorized Start-Up

Features

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Increases adaptability with an open architecture configurable to any IT environment.

Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.

Increases availability by allowing the UPS to be connected to two separate power sources.

Customize UPS capabilities with management cards.

Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Delivers higher availability through redundant batteries.

Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Provides notification of changing utility power and UPS conditions

Prolongs battery life by regulating the charge voltage according to battery temperature.

Allows additional run time to be quickly added as needed.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Reduces UPS over-sizing costs today by allowing quick upgrades later.

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Increases total power capacity by using multiple UPSs simultaneously.

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Power the connected equipment with multiple UPSs to increase system redundancy

Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Provides remote management of the UPS over the network.

Prevents unauthorized access to the UPS.

Enables centralized management via the APC InfraStruXure Manager.

Minimizes installation costs by enabling the use of smaller generators and cabling.

Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

Modular design provides scalable solutions to add cooling as demand increases.

Allows quick, easy battery replacement.

Text and mimic diagrams that display modes of operation, system parameters and alarms.

Simplifies installation and maintenance while minimizing space requirements.

Reduces installation costs by eliminating the need for an external mechanical bypass.

Features & Benefits

Availability

Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Delivers higher availability through redundant batteries.

Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Provides remote management of the UPS over the network.

Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Agility

Reduces UPS over-sizing costs today by allowing quick upgrades later.

Allows additional run time to be quickly added as needed.

Simplifies installation and maintenance while minimizing space requirements.

Ensures compatibility with different input frequencies.

Customize UPS capabilities with management cards.

Allows quick, easy battery replacement.

Total Cost of Ownership

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

Minimizes installation costs by enabling the use of smaller generators and cabling.

Ensures clean, uninterrupted power to protected equipment when generator power is used.

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Required for full coverage of factory warranty

Manageability

Enables centralized management via StruxureWare Central.

Quickly understand unit and power status with visual indicators.

Provides notification of changing utility power and UPS conditions

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.